Made In Great Britain

Direct from our factory

Delivered to Ireland

VAT and duties included

Product Test Results

All test results published

Expert Technical Advice

Call or chat with our team

Overview

Overview ⓘ

This test measures how much liquid water a coated masonry surface takes up by capillary action. The result is a w-value, and a lower figure means less rain gets through the coating into the wall.

Masonry and concrete are porous. Left bare, they draw water in by capillary action, the way a sponge does. This test measures how far a coating cuts that down.

What the test measures

The test measures the rate at which a coated, porous surface absorbs liquid water. The result is the liquid water transmission rate, written as the w-value.

Its unit is kg/(m²·h0.5): kilograms of water, per square metre of surface, per square root of hours. The square root is there because capillary uptake slows as the material fills.

How the test is carried out

The method is EN 1062-3, the European standard for coatings on exterior masonry and concrete.

  • The coating is applied to a porous test block and left to cure.
  • The other faces of the block are sealed, so water can only enter through the coating.
  • The block is conditioned, weighed, and placed with the coated face in water.
  • It is taken out and weighed at set times over 24 hours.
  • The gain in weight, plotted against the square root of time, gives the w-value.

How to read the result

Lower is better. A lower w-value means less water passes through the coating.

EN 1062-1 sorts results into three classes.

Class Water permeability w-value, kg/(m²·h0.5)
W1 High Above 0.5
W2 Medium Above 0.1, up to 0.5
W3 Low 0.1 or below

The numbering runs against instinct. W3 is the class that lets the least water in.

What it means in use

Water in a wall is the cause of most masonry problems. It carries salts to the surface, where they dry as white deposits. It freezes and breaks the face of brick and render. It feeds algae and lowers the insulating value of the wall.

A coating with low water permeability keeps rain out of the surface. To let moisture already in the wall escape, it also needs to pass water vapour. That is a separate test with its own classes, so read the two results together.

What the result does not tell you

The w-value is measured on a sound, fully coated block. On a building, water gets in through cracks, open joints, failed pointing and missed areas. A W3 coating does not stop water entering behind it.

The test uses water under no pressure. It is not a test of tanking, and it does not show that a coating resists standing water or water pushing through from the other side.

It is also a test for wall coatings. It does not describe how a floor coating resists ponding or washing down.

On our product pages

Where a product has been tested, its page shows the result, the method and, where the method has one, the rating. Results published on this site come from internal testing to the stated method. They are given for technical reference and comparison.

If a figure you need is not shown, ask our technical team.

Leave a comment

Please note, comments need to be approved before they are published.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Latest Stories

This section doesn’t currently include any content. Add content to this section using the sidebar.